LIMITED Tenders/Contracts/Purchases of goods/services floated/awarded by the Company
Note: Only REGISTERED VENDORS may submit their quotation. For registration as vendor, please refer Vendor Registration Page under "Tender" from homepage.
Year Month LIMITED TENDERS FLOATED BY THE COMPANY CONTRACTS AWARDED BY THE COMPANY
    Division Sl.No. Tender/Enquiry No. Date of Publication of Tender/Enquiry Item/Nature of Work Type of Bidding (Single(1)/ Two Bid(2) System) Last date of receipt of tender No. of Tenders received Nos. and names of parties qualified after technical evaluation Nos. and names of parties not qualified after technical evaluation Whether contract awarded to Lowest tenderer(L1)/      Evaluated L1(E1) Contract No. and Date Name of    Contractor Value of Contract (Rs.L) Scheduled date of completion of supplies  
    Description Unit Qty.
   
                                     
2007 Feb PR 1 PROJ/DVC-BIADA/019 1-Feb-07 Post Insulator Stack for 33KV system comprising 2 units of 22KV class medium duty post insulator including bolts and nuts as per enclosed technical specification. stacks 48 Single(1) 10-Feb-07 2 2 (Ashoka Tools Pvt. Ltd., Shree Trading Company) Nil Lowest tender(L1) BLL/PROJ/DVC-BIADA/ORD/018 Dt. 21.02.07 Ashoka Tools Pvt. Ltd. 187890 30 days from drawing & GTP approval.
            11KV Disc Insulator as per enclosed technical specification                        
            70 KN Nos. 27                    
            22KV Class Medium Duty, Post Insulator as per enclosed technical specification. stacks 144                    
                                     
    CN-SGW 2 BLL/282 1-Feb-07 CR/CRCA SHEETS 131000 KGS 1 10-Feb-07 2 N/A N/A L(2)(L1-Back out) HR/42201,DT.28.03.2007 S.K.INDUSTRIAL CORPORATION 11.8 MAY'2007
                            Part quantity        
                                     
      3 BLL/283 1-Feb-07 TOOLS 74 NOS 1 8-Feb-07                
                                     
    ADM-SGW 4 AD/ENQ/0263 2-Feb-07 NEW FENCING WITH BARBED WIRE AT SGW NO   1 19-Feb-07                
                                     
    CN-MBW 5 PUR/8653/AS 3-Feb-07  NEW COMMUTATOR WITH ETP GRADE AS PER SAMPLE. COPPER SEGMENT-276.                                     RISER DIA-410MM, SEG DIA- 352, NO. OF SEGMENT: 276, SEG LENGTH- 207MM,RISER WIDTH- 20MM, MATERIAL-E.T.P.GR ELECTROLYTE COPPER.OLD STEEL HUB SHOULD BE REUSED . NO. 1 1 10-Feb-06 2 THE BENGAL COMMUTATOR WORKS, COMMUTATOR MFG.   L1 MB/10891/ER  24/3/2007 THE BENGAL COMMUTATOR WORKS. 135200 30 DAYS.
                                     
    CN-SGW 6 BLL/284 5-Feb-07 TRANSFORMER OIL 4180 LTR 1 13-Feb-07 3 N/A N/A L(1) HR/42040, DT.15.2.07 INDIAN PETRO PRODUCTS 2.65 FEB'07
                                     
    IM 7 ENQ/BLL/2006-07/11 06.02.2007 Server with following Configuration No 1 1 15.02.2007                
            Intel P4 Procesor , 3.GHz at 800 MHz FSB and I MB L2 Cache                        
            Intel E7221 chipset, 1 GB DDR RAM ECC,                        
            ATI ES1000 with 8 MB of video memory,                        
            2*Ps/2, 1* Serial Ports, 2*USB, 1 * Parallel port                        
            2*32 Bit/33 MHz(5v), 1*PCI Express 4X,                        
            1*PCI exp 8 x slots,Onboard Dual Enet                        
            U320 SCSI Controller Card,52XCD ROM                        
            73 GB U320 SCSI HDD 10K RPM,                        
            1.44 MB Floppy Drive, Midtower Cabinet                        
            15" CRT Color Monitor,                        
            107 Keys MEMBRANE keyboard,                        
            PS/2 Optical Scroll Mouse, 20/40 GB Dat Drive                        
                                     
                                     
                                     
    CN-MBW 8 PUR/8671/AS 8-Feb-07 SINGLE ROW ANGULAR CONTACT BALL BEARING - 7326B   2 1 8-Feb-07                
                                     
    CN-MBW 9 PUR/8672/AS 8-Feb-07  NEW COMMUTATOR WITH ETP GRADE AS PER SAMPLE. COPPER SEGMENT-276.                                     RISER DIA-410MM, SEG DIA- 352, NO. OF SEGMENT: 276, SEG LENGTH- 207MM,RISER WIDTH- 20MM, MATERIAL-E.T.P.GR ELECTROLYTE COPPER.OLD STEEL HUB SHOULD BE REUSED . NO. 1 1 15-Feb-06 3 THE BENGAL COMMUTATOR WORKS,COMMUTATOR MFG, DOLPHIN ELECTRIC.   L1 MB/10892/ER  24/3/2007 THE BENGAL COMMUTATOR 145600 30 DAYS.
                                     
    CN-MBW 10 PUR/8673/AS 8-Feb-07 35 SQ. MM  A.T.C.C  6.6KV  GR. CABLE,                 BP-28654 , UNISTAR MT 100 1 15-Feb-07 4 BHATTER ELECTRICALS,MACHINERY AND SPARE PARTS,NISHANT MARKETING,SINHA INSULATED CABLE.   L1 MB/10842/ER  2/3/2007 BHATTER ELECTRICALS & ELECTRONICS. 115300 WITHIN 6 WEEKS.
                                     
    CN-MBW 11 PUR/8669/AS 8-Feb-07  DGC COPPER CONDUCTOR CL-H,G2 BARE SIZE: (3.05 +/- .3 X 9.25 +/- .05 ) MM2.  GRADE OF COVERING:G2. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 240   13-Feb-07   PARAMOUNT CONDUCTOR         SWARNAGIRI WIRE  INS. P. LTD.   L1 MB/10798/ER    17/02/07 PARAMOUNT CONDUCTOR 95810 7 DAYS.
                                     
    ADM-SGW 12 AD/ENQ/0266 10-Feb-07 SUMMER UNIFORM FOR THE YEAR 2007 NO   1 24-Feb-07                
    ADM-SGW 13 AD/ENQ/0267 10-Feb-07 SHOE FOR THE YEAR 2007 NO   1 28-Feb-07 2 1)Shreeleathers Pvt.Ltd. 2) Elite Shoe Company N/A L1 AD/HR/1972/WLF Dt. 04.04.2007 M/s. Sreeleathers Pvt. Ltd. 0.87 30.04.2007
                                     
    CN-MBW 14 PUR/8686/AS 12-Feb-07  EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (3.3 +/- 0.03 X 5.55 +/- 0.05) MM2.  GRADE OF COVERING:E1G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 30-40 BHN CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 390 1 16-Feb-07                
                                     
    CN-SGW 15 BLL/285 15-Feb-07 COPPER CONTACTS 75 NOS 1 22-Feb-07 2 N/A N/A L(1) HR/42084, DT.26.2.07 NAVEEN INDUSTRIES 0.17 MARCH'07
                                     
    CN-MBW 16 PUR/8705/AS 19-Feb-07 REPLACEMENT OF RISER AND REMICA OF COMMUTATOR                                                      DESC:  REMICA OF OLD COMMUTATOR AS PER SAMPLE. REPLACEMENT OF OLD RISER WITH NEW ONES,V CONES AND DRUM INSULATION .ASSEMBLY OF REMICA COMMUTATOR AT YOUR WORKS.                   DIA OF COMMU. SEG: 800MM , SEG. LENGTH: 441MM, RISER DIA: 1186MM, NO. OF SEGMENT: 441, RISER WIDTH: 20MM. NO 1 1 26-Feb-07   THE BENGAL COMMUATOR          DOLPHIN ELECTRIC   L1 MB/10875/ER  19/3/07 BENGAl COMMUTATOR 198700 45 DAYS
                                     
                                     
    CN-MBW 17 PUR/8706/AS 19-Feb-07  EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (4.5 +/- 0.03 X 1.5 +/- 0.03) MM2.  GRADE OF COVERING:E2G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 45-50 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 230 1 24-Feb-07   SWARNAGIRI WIRE INS P.LTD   L1 MB/10857/ER   13/3/2007 SWARNAGIRI WIRE INS P.LTD 103598.92 WITHIN 3 WEEKS.
                                     
    CN-MBW 18 PUR/8707/AS 19-Feb-07  EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (1.00 +/- 0.03 X 8.00 +/- 0.03) MM2.  GRADE OF COVERING:E1G1. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 125 1 24-Feb-07                
                                     
                                     
    CN-MBW 19 PUR/8708/AS 19-Feb-07  EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (4.00 +/- 0.05 X 2.6 +/- 0.03) MM2.  GRADE OF COVERING:E2G1. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 180 1 24-Feb-07   PARAMOUNT CONDUCTOR        SWARNAGIRI WIRE INSULATION   L1 MB/10858/ER   13/3/2007 SWARNAGIRI WIRE INS. 78464.41 WITHIN 3 WEEKS
                                     
        PUR/8696A/SP 19-Feb-07 ROTOR CU. BAR, ELECTROLYTE HARD DRAWN CU.     1 26/02/2007 2 MA-KALI ENGG. WORKS, J.S. INDUSTRIES NIL L1 10840    1/3/2007 MA-KALI ENGG. WORKS 0.87 21 DAYS
                                     
    CN-ADM 20 AD/ENQ/0273 19-Feb-07 Swabing of Shop Floor at Switchgear Works NO   1 26-Feb-07                
                                     
    IM 21 ENQ/BLL/2006-07/12 19.02.2007 600 VA UPS No 60 1 28.02.2007 4 G.P.Tronics Pvt.Ltd., Myrinda Systems, ARC Infotech Pvt.Ltd., OPTO Audio Electronic Product Pvt. Ltd. Nil L1 ITE011/NIH/39 date - 05.03.2007 G.P. Tronics Pvt.Ltd. 1.17 Witinin 2 weeks
                                     
    CN-ADM 22 AD/ENQ/0274 19-Feb-07 DEVELOPMENT & MAINTENANCE OF 2 NOS. OF GARDEN AT SGW NO   1 26-Feb-07                
                                     
    CN-MBW 23 PUR/8711/AS 21-Feb-07  EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (7.5 +/- 0.05 X 1.8 +/- 0.03) MM2.  GRADE OF COVERING:E2G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 40-45 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER  IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. KG. 265 1 27-Feb-07   PARAMOUNT CONDUCTOR        SWARNAGIRI WIRE INSULATION   L1 MB/10856/ER   13/3/2007 SWARNAGIRI WIRE INS. 119363.98 WITHIN 3 WEEKS.
                                     
    CN-MBW 24 PUR/8713/AS 21-Feb-07  MFG. OF NEW COMMUTATOR AS PER SAMPLE.  NO. OF SEGMENT-150, RISER DIA - 494 MM. RISER WIDTH-22MM SEG. DIA - 413 MM. SEG.  LENGTH -335 MM.   OLD SAMPLE  WILL BE SUPPLIED BY US. ALL RELEVENT TEST CERTIFICATES SHOULD BE SUBMITTED AT THE TIME OF DELIVERY.TEST VOLTAGE-SEG.-SEG.-750V A.C. SEG.TO EARTH-5 KV. .COMPLETION PERIOD 35 DAYS. NO. 1   28-Feb-07 2 THE BENGALCOMMUTATOR,DOLPHIN ELECTRIC (I), NIL L1 10920 05/04/2007 THE BENGAL COMMUTATOR 213200.00 30 DAYS  
                                     
    CN-MBW 25 PUR/8714/AS 21-Feb-07  NEW COMMUTATOR WITH WITH SILVER BEARING. COPPER SEGMENT-162.                                     RISER DIA-492MM, SEG DIA- 435, NO. OF SEGMENT: 162, SEG LENGTH- 205MM,RISER WIDTH- 20MM, MATERIAL: SILVER BEARING COMMUTATOR,SILVER CONTAIN SHOULD BE MORE THAN 0.06%. OLD STEEL HUBS TO BE REUSED. NO. 1 1 28-Feb-06   THE BENGAL COMMUATOR          DOLPHIN ELECTRIC   L1 MB/10876/ER  19/3/07 DOLPHIN ELECTRIC 192400 30 DAYS