| LIMITED Tenders/Contracts/Purchases of goods/services floated/awarded by the Company | |||||||||||||||||||
| Note: Only REGISTERED VENDORS may submit their quotation. For registration as vendor, please refer Vendor Registration Page under "Tender" from homepage. | |||||||||||||||||||
| Year | Month | LIMITED TENDERS FLOATED BY THE COMPANY | CONTRACTS AWARDED BY THE COMPANY | ||||||||||||||||
| Division | Sl.No. | Tender/Enquiry No. | Date of Publication of Tender/Enquiry | Item/Nature of Work | Type of Bidding (Single(1)/ Two Bid(2) System) | Last date of receipt of tender | No. of Tenders received | Nos. and names of parties qualified after technical evaluation | Nos. and names of parties not qualified after technical evaluation | Whether contract awarded to Lowest tenderer(L1)/ Evaluated L1(E1) | Contract No. and Date | Name of Contractor | Value of Contract (Rs.L) | Scheduled date of completion of supplies | |||||
| Description | Unit | Qty. | |||||||||||||||||
| 2007 | Feb | PR | 1 | PROJ/DVC-BIADA/019 | 1-Feb-07 | Post Insulator Stack for 33KV system comprising 2 units of 22KV class medium duty post insulator including bolts and nuts as per enclosed technical specification. | stacks | 48 | Single(1) | 10-Feb-07 | 2 | 2 (Ashoka Tools Pvt. Ltd., Shree Trading Company) | Nil | Lowest tender(L1) | BLL/PROJ/DVC-BIADA/ORD/018 Dt. 21.02.07 | Ashoka Tools Pvt. Ltd. | 187890 | 30 days from drawing & GTP approval. | |
| 11KV Disc Insulator as per enclosed technical specification | |||||||||||||||||||
| 70 KN | Nos. | 27 | |||||||||||||||||
| 22KV Class Medium Duty, Post Insulator as per enclosed technical specification. | stacks | 144 | |||||||||||||||||
| CN-SGW | 2 | BLL/282 | 1-Feb-07 | CR/CRCA SHEETS | 131000 | KGS | 1 | 10-Feb-07 | 2 | N/A | N/A | L(2)(L1-Back out) | HR/42201,DT.28.03.2007 | S.K.INDUSTRIAL CORPORATION | 11.8 | MAY'2007 | |||
| Part quantity | |||||||||||||||||||
| 3 | BLL/283 | 1-Feb-07 | TOOLS | 74 | NOS | 1 | 8-Feb-07 | ||||||||||||
| ADM-SGW | 4 | AD/ENQ/0263 | 2-Feb-07 | NEW FENCING WITH BARBED WIRE AT SGW | NO | 1 | 19-Feb-07 | ||||||||||||
| CN-MBW | 5 | PUR/8653/AS | 3-Feb-07 | NEW COMMUTATOR WITH ETP GRADE AS PER SAMPLE. COPPER SEGMENT-276. RISER DIA-410MM, SEG DIA- 352, NO. OF SEGMENT: 276, SEG LENGTH- 207MM,RISER WIDTH- 20MM, MATERIAL-E.T.P.GR ELECTROLYTE COPPER.OLD STEEL HUB SHOULD BE REUSED . | NO. | 1 | 1 | 10-Feb-06 | 2 | THE BENGAL COMMUTATOR WORKS, COMMUTATOR MFG. | L1 | MB/10891/ER 24/3/2007 | THE BENGAL COMMUTATOR WORKS. | 135200 | 30 DAYS. | ||||
| CN-SGW | 6 | BLL/284 | 5-Feb-07 | TRANSFORMER OIL | 4180 | LTR | 1 | 13-Feb-07 | 3 | N/A | N/A | L(1) | HR/42040, DT.15.2.07 | INDIAN PETRO PRODUCTS | 2.65 | FEB'07 | |||
| IM | 7 | ENQ/BLL/2006-07/11 | 06.02.2007 | Server with following Configuration | No | 1 | 1 | 15.02.2007 | |||||||||||
| Intel P4 Procesor , 3.GHz at 800 MHz FSB and I MB L2 Cache | |||||||||||||||||||
| Intel E7221 chipset, 1 GB DDR RAM ECC, | |||||||||||||||||||
| ATI ES1000 with 8 MB of video memory, | |||||||||||||||||||
| 2*Ps/2, 1* Serial Ports, 2*USB, 1 * Parallel port | |||||||||||||||||||
| 2*32 Bit/33 MHz(5v), 1*PCI Express 4X, | |||||||||||||||||||
| 1*PCI exp 8 x slots,Onboard Dual Enet | |||||||||||||||||||
| U320 SCSI Controller Card,52XCD ROM | |||||||||||||||||||
| 73 GB U320 SCSI HDD 10K RPM, | |||||||||||||||||||
| 1.44 MB Floppy Drive, Midtower Cabinet | |||||||||||||||||||
| 15" CRT Color Monitor, | |||||||||||||||||||
| 107 Keys MEMBRANE keyboard, | |||||||||||||||||||
| PS/2 Optical Scroll Mouse, 20/40 GB Dat Drive | |||||||||||||||||||
| CN-MBW | 8 | PUR/8671/AS | 8-Feb-07 | SINGLE ROW ANGULAR CONTACT BALL BEARING - 7326B | 2 | 1 | 8-Feb-07 | ||||||||||||
| CN-MBW | 9 | PUR/8672/AS | 8-Feb-07 | NEW COMMUTATOR WITH ETP GRADE AS PER SAMPLE. COPPER SEGMENT-276. RISER DIA-410MM, SEG DIA- 352, NO. OF SEGMENT: 276, SEG LENGTH- 207MM,RISER WIDTH- 20MM, MATERIAL-E.T.P.GR ELECTROLYTE COPPER.OLD STEEL HUB SHOULD BE REUSED . | NO. | 1 | 1 | 15-Feb-06 | 3 | THE BENGAL COMMUTATOR WORKS,COMMUTATOR MFG, DOLPHIN ELECTRIC. | L1 | MB/10892/ER 24/3/2007 | THE BENGAL COMMUTATOR | 145600 | 30 DAYS. | ||||
| CN-MBW | 10 | PUR/8673/AS | 8-Feb-07 | 35 SQ. MM A.T.C.C 6.6KV GR. CABLE, BP-28654 , UNISTAR | MT | 100 | 1 | 15-Feb-07 | 4 | BHATTER ELECTRICALS,MACHINERY AND SPARE PARTS,NISHANT MARKETING,SINHA INSULATED CABLE. | L1 | MB/10842/ER 2/3/2007 | BHATTER ELECTRICALS & ELECTRONICS. | 115300 | WITHIN 6 WEEKS. | ||||
| CN-MBW | 11 | PUR/8669/AS | 8-Feb-07 | DGC COPPER CONDUCTOR CL-H,G2 BARE SIZE: (3.05 +/- .3 X 9.25 +/- .05 ) MM2. GRADE OF COVERING:G2. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 240 | 13-Feb-07 | PARAMOUNT CONDUCTOR SWARNAGIRI WIRE INS. P. LTD. | L1 | MB/10798/ER 17/02/07 | PARAMOUNT CONDUCTOR | 95810 | 7 DAYS. | ||||||
| ADM-SGW | 12 | AD/ENQ/0266 | 10-Feb-07 | SUMMER UNIFORM FOR THE YEAR 2007 | NO | 1 | 24-Feb-07 | ||||||||||||
| ADM-SGW | 13 | AD/ENQ/0267 | 10-Feb-07 | SHOE FOR THE YEAR 2007 | NO | 1 | 28-Feb-07 | 2 | 1)Shreeleathers Pvt.Ltd. 2) Elite Shoe Company | N/A | L1 | AD/HR/1972/WLF Dt. 04.04.2007 | M/s. Sreeleathers Pvt. Ltd. | 0.87 | 30.04.2007 | ||||
| CN-MBW | 14 | PUR/8686/AS | 12-Feb-07 | EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (3.3 +/- 0.03 X 5.55 +/- 0.05) MM2. GRADE OF COVERING:E1G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 30-40 BHN CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 390 | 1 | 16-Feb-07 | |||||||||||
| CN-SGW | 15 | BLL/285 | 15-Feb-07 | COPPER CONTACTS | 75 | NOS | 1 | 22-Feb-07 | 2 | N/A | N/A | L(1) | HR/42084, DT.26.2.07 | NAVEEN INDUSTRIES | 0.17 | MARCH'07 | |||
| CN-MBW | 16 | PUR/8705/AS | 19-Feb-07 | REPLACEMENT OF RISER AND REMICA OF COMMUTATOR DESC: REMICA OF OLD COMMUTATOR AS PER SAMPLE. REPLACEMENT OF OLD RISER WITH NEW ONES,V CONES AND DRUM INSULATION .ASSEMBLY OF REMICA COMMUTATOR AT YOUR WORKS. DIA OF COMMU. SEG: 800MM , SEG. LENGTH: 441MM, RISER DIA: 1186MM, NO. OF SEGMENT: 441, RISER WIDTH: 20MM. | NO | 1 | 1 | 26-Feb-07 | THE BENGAL COMMUATOR DOLPHIN ELECTRIC | L1 | MB/10875/ER 19/3/07 | BENGAl COMMUTATOR | 198700 | 45 DAYS | |||||
| CN-MBW | 17 | PUR/8706/AS | 19-Feb-07 | EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (4.5 +/- 0.03 X 1.5 +/- 0.03) MM2. GRADE OF COVERING:E2G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 45-50 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 230 | 1 | 24-Feb-07 | SWARNAGIRI WIRE INS P.LTD | L1 | MB/10857/ER 13/3/2007 | SWARNAGIRI WIRE INS P.LTD | 103598.92 | WITHIN 3 WEEKS. | |||||
| CN-MBW | 18 | PUR/8707/AS | 19-Feb-07 | EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (1.00 +/- 0.03 X 8.00 +/- 0.03) MM2. GRADE OF COVERING:E1G1. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 125 | 1 | 24-Feb-07 | |||||||||||
| CN-MBW | 19 | PUR/8708/AS | 19-Feb-07 | EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (4.00 +/- 0.05 X 2.6 +/- 0.03) MM2. GRADE OF COVERING:E2G1. INS. CLASS: 'F' HARDNESS OF CU. SHOULD BE WITHIN 35-40 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 180 | 1 | 24-Feb-07 | PARAMOUNT CONDUCTOR SWARNAGIRI WIRE INSULATION | L1 | MB/10858/ER 13/3/2007 | SWARNAGIRI WIRE INS. | 78464.41 | WITHIN 3 WEEKS | |||||
| PUR/8696A/SP | 19-Feb-07 | ROTOR CU. BAR, ELECTROLYTE HARD DRAWN CU. | 1 | 26/02/2007 | 2 | MA-KALI ENGG. WORKS, J.S. INDUSTRIES | NIL | L1 | 10840 1/3/2007 | MA-KALI ENGG. WORKS | 0.87 | 21 DAYS | |||||||
| CN-ADM | 20 | AD/ENQ/0273 | 19-Feb-07 | Swabing of Shop Floor at Switchgear Works | NO | 1 | 26-Feb-07 | ||||||||||||
| IM | 21 | ENQ/BLL/2006-07/12 | 19.02.2007 | 600 VA UPS | No | 60 | 1 | 28.02.2007 | 4 | G.P.Tronics Pvt.Ltd., Myrinda Systems, ARC Infotech Pvt.Ltd., OPTO Audio Electronic Product Pvt. Ltd. | Nil | L1 | ITE011/NIH/39 date - 05.03.2007 | G.P. Tronics Pvt.Ltd. | 1.17 | Witinin 2 weeks | |||
| CN-ADM | 22 | AD/ENQ/0274 | 19-Feb-07 | DEVELOPMENT & MAINTENANCE OF 2 NOS. OF GARDEN AT SGW | NO | 1 | 26-Feb-07 | ||||||||||||
| CN-MBW | 23 | PUR/8711/AS | 21-Feb-07 | EN. DGC COPPER CONDUCTOR AS PER IS 10114. BARE SIZE: (7.5 +/- 0.05 X 1.8 +/- 0.03) MM2. GRADE OF COVERING:E2G1. INS. CLASS: 'H' HARDNESS OF CU. SHOULD BE WITHIN 40-45 BHN. CONDUCTIVITY OF COPPER SHOULD BE 99.95%. TEST CERTIFICATE SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB AS PER IS 191 PART V.CHEMICAL COMPOSITION TEST SHOULD BE CARRIED OUT FROM GOVT. APPROVED LAB. | KG. | 265 | 1 | 27-Feb-07 | PARAMOUNT CONDUCTOR SWARNAGIRI WIRE INSULATION | L1 | MB/10856/ER 13/3/2007 | SWARNAGIRI WIRE INS. | 119363.98 | WITHIN 3 WEEKS. | |||||
| CN-MBW | 24 | PUR/8713/AS | 21-Feb-07 | MFG. OF NEW COMMUTATOR AS PER SAMPLE. NO. OF SEGMENT-150, RISER DIA - 494 MM. RISER WIDTH-22MM SEG. DIA - 413 MM. SEG. LENGTH -335 MM. OLD SAMPLE WILL BE SUPPLIED BY US. ALL RELEVENT TEST CERTIFICATES SHOULD BE SUBMITTED AT THE TIME OF DELIVERY.TEST VOLTAGE-SEG.-SEG.-750V A.C. SEG.TO EARTH-5 KV. .COMPLETION PERIOD 35 DAYS. | NO. | 1 | 28-Feb-07 | 2 | THE BENGALCOMMUTATOR,DOLPHIN ELECTRIC (I), | NIL | L1 | 10920 05/04/2007 | THE BENGAL COMMUTATOR | 213200.00 | 30 DAYS | ||||
| CN-MBW | 25 | PUR/8714/AS | 21-Feb-07 | NEW COMMUTATOR WITH WITH SILVER BEARING. COPPER SEGMENT-162. RISER DIA-492MM, SEG DIA- 435, NO. OF SEGMENT: 162, SEG LENGTH- 205MM,RISER WIDTH- 20MM, MATERIAL: SILVER BEARING COMMUTATOR,SILVER CONTAIN SHOULD BE MORE THAN 0.06%. OLD STEEL HUBS TO BE REUSED. | NO. | 1 | 1 | 28-Feb-06 | THE BENGAL COMMUATOR DOLPHIN ELECTRIC | L1 | MB/10876/ER 19/3/07 | DOLPHIN ELECTRIC | 192400 | 30 DAYS | |||||